EasyManuals Logo

Telit Wireless Solutions ME910G1 Series User Manual

Telit Wireless Solutions ME910G1 Series
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
ME910G1 HW Design Guide
1VV0301593 Rev.3 Page 56 of 97 2020-03-24
3 receivers
An example of RS232 level
adaptation circuitry could be done
using a MAXIM transceiver
(MAX218)
In this case the chipset is capable
to translate directly from 1.8V to
the RS232 levels (Example done
on 4 signals only).
The RS232 serial port lines are usually connected to a DB9 connector with the following
layout:
General purpose I/O
The ME910G1 module is provided by a set of Configurable Digital Input / Output pins
(CMOS 1.8V). Input pads can only be read; they report the digital value (high or low)
present on the pad at the read time. Output pads can only be written or queried and set
the value of the pad output.
An alternate function pad is internally controlled by the ME910G1 firmware and acts
depending on the function implemented.