ME910G1 HW Design Guide
1VV0301593 Rev.3 Page 60 of 97 2020-03-24
Item
Min
Typical
Max
Unit
Input Voltage range
0
-
1.8
Volt
AD conversion
-
-
10
bits
Input Resistance
1
-
-
Mohm
Input Capacitance
-
1
-
pF
The ADC could be controlled using an AT command.
The command is AT#ADC=1,2
The read value is expressed in mV
Refer to SW User Guide or AT Commands Reference Guide for the full description of this
function.