Moisture Sensitivity
The ME910X1-mPCIe is a Moisture Sensitive Device level 3, in accordance with the
standard IPC/JEDEC J-STD-020, take care all the relatives requirements for using this
kind of components.
Moreover, the customer has to take care of the following conditions:
a) Calculated shelf life in sealed bag: 12 months at <40°C and <90% relative humidity
(RH).
b) Environmental condition during the production: 30°C / 60% RH according to
IPC/JEDEC J-STD-033A paragraph 5.
c) The maximum time between the opening of the sealed bag and the reflow process
must be 168 hours if condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is
respected
d) Baking is required if conditions b) or c) are not respected