Section 3 - Step-By-Step Assembly
Temp-Cast 2000 Installation Manual
15
STEP 5:
Install Parts# 10, 11, 12 &13, using refractory mortar. Also “butter” the ends of part #10, so there
are no gaps on the ends. (Note that parts 11 thru 13 are identical to the previous course.) (In the
"See-Through" fireplace, there is no part #11.)
Seat with the rubber mallet and ensure that joints are tight.
Remember to keep the front edges of the modules aligned and use a 48” level to ensure that the
four sides are plumb.
Leveling the courses is not critical – it is sufficient if the courses are approximately level.
Weights
#10 - 12 lbs
#11 - 52 lbs
#12 & #13 - 68 lbs
#12ST & #13ST - 68 lbs