20.2 Inductance Setting - Mig/Mag Synergic
The value of electronic inductance is automatically adjusted with the synergic
preset, value can be adjusted as follow.
Display shows the increasing or decreasing pourcentage towards the pre-set
(synergic) value.
A -press until inductance led light on
B – adjust inductance
20.3 ARC setting - Mig/Mag Synergic
The main knob allows arc setting between -20 (short) and +20 (long). The -0- value
correspond than to the pre-set synergic value.
In the same way you can adjust POST GAS, TIMER, CRATER FILLER
and TRIGGER mode.
20.4 Setting from the Remote Wire Feeder Unit
Mig/Mag Synergic
First of all, set the MIG/MAG synergic mode on the generator main panel: