4.1 Power supply to analyser box
Mains adapter :
Attach mains adapter to the analyser box
.
testo rechargeable battery pack (0515 0098)
1
Unlock catch
.
2
Connect adapter. Ensure that the plug snaps into place .
Observe markings on adapter.
Do not kink or damage cable!
3
Replace cover and close.
Recharging the rechargeable battery pack
Recharge rechargeable battery pack prior to first use.
It is not possible to recharge during operation.
·
The instrument must be switched off.
·
The rechargeable battery pack must be inserted in the logger for recharging.
Insert mains cable (230 V AC) into analyser box.
·
Recharging the analyser box:
·
Recharging is in progress: LED flashes green,
·
Recharging is complete: LED lights up green.
An empty rechargeable battery needs up to approx. 3-4 hours for complete recharging.
4.2 Power supply to Control Unit
Mains unit (0554 1084):
Connect mains unit to Control Unit
.
Batteries/Standard rechargeable batteries:
1
Release lock
.
2
Insert batteries. Watch out for +/- .
3
Replace cover and close.
The batteries can remain inside the instrument during mains operation.
Recharging is not possible with batteries/standard rechargeable batteries.
testo rechargeable battery pack (0515 0097):
1
Release lock
.
2
Insert plug .
Observe markings on plug.
Do not kink or damage cable!
3
Insert the rechargeable battery pack such that the rechargeable battery pack label is
visible from above
.
4
Replace cover and close.