34
EN
620
8.
Set the lter pump switch to “STOP”.
Power up the control panel by setting the main
switch to “ON”.
The ller solenoid valve will cut in automatically to
bring the water up to operating level in the overow
tank.
Set the lter selector valve to “3” (RINSE).
Set the pump switch to “MAN” (manual).
Water will now ow from the overow tank into the
lter, washing the sand, and from the lter directly
to the drain.
After 30-40 seconds operation, shut off the rinse
ow by setting the pump switch to “STOP”.
9.
Shift the selector lever to position “1” (FILTER) .
Set the pump switch to “MAN” (manual).
Water will begin owing from the pool through the
lter.