Premier 48, 88, 168 & 640 Installation Manual Installation
INS176 17
OP16 Output Expander
Output Module Layout
Power LED
Tamper
Switch
Network
Term in als
A
ux 12V
and Tamper
Output
NETWORK IN
+
-
TR
+
-
TR
NETWORK OUT
Power
1Amp Aux 12v
1
mp
2431
BANK 1
Remote
Bank 2
Outputs
1 to 8
1
2
3
4
5
6
7
8
BANK 2
1
2
3
4
5
6
7
8
BANK 1
Bank 1
Outputs
1 to 8
Tmp
-
Aux 12V
++
-
2431
BANK 2
Network
Ter mi na ls
Engineers
Keypad
Interface
Connecting Output Modules
Output modules are connected to the network terminals
located at the bottom left hand corner of the control panel
(see pages 12 & 13 for details).
Output Module Addressing
Each output module must be assigned a different address
using the DIL switches located in the centre of the PCB.
The table below shows the expander addressing:
Address DIL 1 DIL 2 DIL 3 DIL 4
1 On or off Off Off Off
2 431
2 Off On Off Off
2 431
3* Off Off On Off
2 431
4* Off Off Off On
2 431
5 ** On Off Off On
2
4
3
1
6 ** Off On Off On
2 431
7 ** Off Off On On
2
4
3
1
8 ** On Off On On
2
4
3
1
Disabled On On On On
2
4
3
1
* Premier 88, 168 and 640 only
** Premier 168 and 640 only
In order for an output module to mimic zone expander
outputs, the output module must be addressed the
same as the zone expander that it is mimicking.
Any combination of addresses can be used on each
output module i.e. Bank 1 can be addressed to mimic
expander 3 and Bank 2 can be addressed to mimic
expander 8.
Bank 1 switch sets the address of the device that Bank
1 outputs 1 to 8 will mimic.
Bank 2 switch sets the address of the device that Bank
2 outputs 1 to 8 will mimic.
Output Module Numbering
The table below shows the output allocation when the
output modules are installed:
Address
Outputs
(Network 1)
Outputs
(Network 2) **
1
Expander 1, 1 - 8 Expander 1, 1 - 8
2
Expander 2, 1 - 8 Expander 2, 1 - 8
3 *
Expander 3, 1 - 8 Expander 3, 1 - 8
4 *
Expander 4, 1 - 8 Expander 4, 1 - 8
5 **
Expander 5, 1 - 8 Expander 5, 1 - 8
6 **
Expander 6, 1 - 8 Expander 6, 1 - 8
7 **
Expander 7, 1 - 8 Expander 7, 1 - 8
8 **
Expander 8, 1 - 8 Expander 8, 1 - 8
* Premier 88, 168 and 640 only
** Premier 168 and 640 only
Network 2 can only be used on the Premier 168.
For Premier 640 see page 18 for details
Outputs
The output module has 16 programmable outputs, which can
be used to drive auxiliary devices such as LED’s, sounders or
relays etc. Wire as per Panel Outputs shown on page 21 (see
page 60 for details). The electrical characteristics for the
outputs are shown below:
Bank Outputs Max Current Type
1 1 to 8 100mA Switched -ve
2 1 to 8 100mA Switched -ve
Tamper Output
The tamper switch on the output module is connected to the
tamper output at the top of the module. If monitoring of the lid
tamper is required, this output must be connected to a
suitable input on the control panel or zone expander.