System Overview Premier 48, 88, 168 & 640 Installation Manual
4 INS176
1. System Overview
System Architecture
8 Programmable
100mA Outputs
Bell Tamper Input
Auxiliary Tamper Input
5 Programmable
A & 1 Relay)
( and 640only)
Premier 88, 168
Outputs
(4 x 500m
Premier
48/88/168/640
Premier LCD/LCDP
4 Wire Data Network 1 & 2
(2 = only)
Premier 168
16 Programmable
100mA Outputs
4 Keypads ( )
Keypads ( )
64 Keypads ( )
Premier 48
Premier 168
Premier 640
8 Keypads ( )
16
Premier 88
Premier OP16
2 Output Modules ( )
Output Modules ( )
32
Premier 48
Premier 168
4 Output Modules ( )
8
Premier 88
Output Modules ( )
Premier 640
8 Zone Inputs
A
larm Receiving
Centre
Modem
PC and Modem for
Remote Upload/Download
PC-Com
PC and for
Local Upload/Download
PC-Com
Plug on Digimodem
Plug on
(Com300, Com2400
or ComISDN)
Radio-Pad,
GSM Module
2 Zone
Inputs
1Programmable
100mA Output
2 Zone
Inputs
1Programmable
100mA Output
Speaker
Output
4 Wire Data Network 2-8
(only)
Premier 640
Speaker Output
8 Zone Inputs
Auxiliary Input
Premier 8XP
8 Programmable
100mA Outputs
4 Expanders ( )
Expanders ( )
Premier 48
Premier 168
8 Expanders ( )
16
Premier 88
64 Expanders ( )
Premier 640
8 to 48 Zones ( )
()
2 to 640 Zone
Premier 48
Premier 168
8 to 88 Zones ( )
8 to 168 Zones
Premier 88
s ( )
Premier 640
Power
Info.
Ready
ServiceOmi
Power
Info.
Ready
ServiceOmit
Bell/Strobe Outputs
Area
Yes
Part
Chime
Omit Reset
Menu
2
abc
No
1
3
def
6
mno
9
wxyz
5
jkl
8
tuv
0
4
ghi
7
pqrs
Area
Yes
Part
Chime
Omit Reset
Menu
2
abc
No
1
3
def
6
mno
9
wxyz
5
jkl
8
tuv
0
4
ghi
7
pqrs
Premier
Control Panels
Premier 48
8 fully programmable Double Pole or End Of Line zones
Expandable to 48 zones via keypads and zone expanders
1 x 4-wire data network (standard 7/0.2 alarm cable)
Up to 4 keypads and 4 zone expanders
Up to 2 output modules
4 independent areas each with 3 part arms
4 area arm suites
25 programmable User codes
500 Event Log (time & date stamped)
2 programmable panel outputs (2 x 1A )
1.5 Amp power supply
Premier 88
8 fully programmable Double Pole or End Of Line zones
Expandable to 88 zones via keypads and zone expanders
1 x 4-wire data network (standard 7/0.2 alarm cable)
Up to 8 keypads and 8 zone expanders
Up to 4 output modules
8 independent areas each with 3 part arms
8 area arm suites
50 programmable User codes
1000 Event Log (time & date stamped)
5 programmable panel outputs (4 x 1A & 3A relay)
2.0 Amp power supply
Premier 168
8 fully programmable Double Pole or End Of Line zones
Expandable to 168 zones via keypads and zone expanders
2 x 4-wire data network (standard 7/0.2 alarm cable)
Up to 16 keypads and 16 zone expanders (8 per network)
Up to 8 output modules (4 per network)
16 independent areas each with 3 part arms
16 area arm suites
100 programmable User codes
2000 Event Log (time & date stamped)
5 programmable panel outputs (4 x 1A & 3A relay)
2.0 Amp power supply
Premier 640
Expandable to 640 zones via keypads and zone expanders
8 x 4-wire data network (standard 7/0.2 alarm cable)
Up to 64 keypads and 64 zone expanders (8 per network)
Up to 32 output modules (4 per network)
16 independent areas each with 3 part arms
100 programmable User codes
2500 Event Log (time & date stamped)
5 programmable panel outputs (4 x 1A & 3A relay)
2.0 Amp power supply

Table of Contents