Monitor Hardware
1,")" 1BX
),)-1&,+0
Yes
),)-1&,+0
,+&1,//!4/"
Yes
3
def
),)-1&,+0
601"*&*"/0
No
Yes
4/"
H
No
Press NO to edit
the options
Use keys 1 - 8 to select
an attribute or use the
SCROLL key to search
Press NO to
select/deselect
the option
1%2)10
FH
"))*-"/
FH
"))*-"/
FHH
The control panel monitors many inputs for fault conditions
i.e. the panel lid tamper, bell tamper, aux fuse etc.
Each one of these options can be disabled to overcome
problems related to the devices being monitored.
P - ATS Path Faults
The Alarm Transmission System is monitored for faults.
A - AC Power Failure
The AC Mains is monitored for faults.
F - Aux Fuse Blown
The Auxiliary Fuse/PTC is monitored for faults.
B - Bell Tamper
The external sounder tamper loop is monitored for faults.
A - Aux Tamper
The auxiliary tamper loop is monitored for faults.
L - Panel Lid Tamper
The control panel lid tamper is monitored for faults.
B - Battery Faults
The battery is monitored for faults.
Control Timers
1,")" 1BX
),)-1&,+0
Yes
Yes
4
ghi
),)-1&,+0
601"*&*"/0
*"/0
Yes
Use keys 1 - 8 to select
the days 1 = Sunday
through to 7 = Saturday
(8 = Holiday Date)
e.g. 1 = Sunday
1
&0+1F9;B88
Use the SCROLL key to
select control timer 1 - 8
,+1/,)&*"/:
&0+1F99B=:
Enter the ‘a’ On time
for e.g. 1152 = 11:52 am
Press YES to select
the ‘a’ On Time
‘DAYS OF OPERATION’
&*"/:+60
YYYYYYYYYYYYYYYY
&*"/:+60
2YYYYYYYYYYYYYY
Yes
Yes
Use keys 1 - 8 to select the
days e.g. 3 = Tuesday
1
Enter the ‘a’ Off Time
for e.g. 2134 = 9:34 pm
Press YES to select
the ‘a’ Off Time
‘DAYS OF OPERATION’
&*"/:##60
YYYYYYYYYYYYYYYY
&*"/:##60
YYYY2YYYYYYYYYY
Press YES to select
the ‘a’ Off Time
,+1/,)&*"/:
&0##1F:9B;<
????
????
The Premier 48 has 4 control timers and the Premier 88, 168 and
640 all have 8 control timers. Each timer has two ON and OFF
times (a & b), and can be programmed to operate on any day of
the week. Once configured, the timers can be used to arm or
disarm areas, lockout users and control outputs.
When programming the Control Timers ON time,
pressing
will bring a ‘*’ up on the display. This ‘*’
indicates that the internal sounders will chime every
time the Control Timers ON time is reached.
When programming the Control Timers DAYS of
operation, pressing
will bring ‘HO’ up on the
display. This ‘HO’ indicates that the control timer will
operate on any programmed Holiday date.