Premier 48, 88, 168 & 640 Installation Manual Programming the Control Panel
INS176 87
User Options 1
This menu defines which options are available to the user
when their code is entered.
Press
to scroll through the options and press
to
select them or use keys
-
(‘Letter’ = option IS
selected, ‘Star’ = option is NOT selected).
The following options are available:
A - Arming
Areas assigned to the selected user can be armed.
D - Disarming
Areas assigned to the selected user can be disarmed.
O - Omitting
Zones assigned to the same areas as the selected user can
be omitted, providing that they have the ‘omit’ attribute
assigned to them.
R - Eng. Reset (Engineers only)
Areas programmed as ‘Engineer reset’ can be reset after an
Alarm has occurred.
a - Local Arming
The User can only arm areas that the keypad is assigned to.
d - Local Disarm
The User can only disarm areas that the keypad is assigned to,
or areas that are in entry or alarm (provided that the code has
that area assigned to it).
Y - Auto ‘YES’
After a User code has been entered, pressing the
key to
confirm the next action is not required.
F - Disarm First
If an area is already armed and the selected user enters their
code, the ‘Disarm’ option is displayed.
User Options 1
This menu is only displayed if the Custom User type is
selected (see page 86 for details).
This menu defines which options are available to the user
when their code is entered.
Press
to scroll through the options and press
to
select them or use keys
-
(‘Letter’ = option IS
selected, ‘Star’ = option is NOT selected).
The following options are available:
U - User Menu
The selected user has access to the User menu. However,
the selected user will only have access to options assigned in
‘User Config.’ (see page 88 for details).
E - Eng. Program (Engineers only)
Only Available to Engineers.
D - Dual Code
The selected user can only access an area when a second
User code (with the ‘Dual Code’ attribute and also assigned
to the same area) is entered. Dual Code users will also
activate the ‘1
st
and 2
nd
Code’ output type.
V - Vacation
The selected user is enabled the first time it is used to disarm
the system and can be used as many times as required.
However, it will be automatically deleted the first time that the
User 01 code is used to disarm. Vacation users will only be
deleted by the Master user, once they have been used on the
system.
S - Door Strike
The selected user will activate any outputs programmed as
‘Door Strike’, whenever their codes are entered.
R - Call Rem. PC
The selected user has access to the ‘Call Remote PC’ option,
allowing them to initiate a call to a remote upload/download
PC.
C - Duress Code
The selected user will activate any outputs programmed as
‘Duress’, whenever their codes are entered.
O - Open/Close
The selected user will report open (disarm) and close (arm)
events to an Alarm Receiving Centre every time they arm or
disarm.