User Functions Menu Premier 8SP Master User Manual
10 INS237
3. User Functions Menu
This section covers the more advanced functions that
selected users can perform with the alarm system. The
following functions are available:
Reset Alarms
This function is used to reset any standing alarms and
service faults. It is also used to reset detectors with a latched
alarm indication, e.g., Smoke Detectors.
" To Reset Alarms, proceed as follows:
Premier 8SP
17:30.21 28/04
YES to Arm?
MENU for Options
The keypad will bleep and the alarm system will reset
all latching detectors and attempt to clear any standing
or .Alarms Service Faults
Press N0
Enter Access code ????
Press R
Armed
Zones
87654321
Ready
Alarm
Service
Armed
Zones
87654321
Ready
Alarm
Service
1
2
3
Last Alarm Log
The control panel has a memory that stores the zones that
caused an alarm when the system was last armed.
" To view the alarm memory, proceed as follows:
Last Alarm From:
Zone 03
YES to Arm?
MENU for Options
The keypad will display the zones that caused an alarm
when the system was last armed.
Press to return to the normal disarmed state.N
Press N1
Enter Access code ????
Armed
Zones
87654321
Ready
Alarm
Service
1
2
3
Armed
Zones
87654321
Ready
Alarm
Service
Last Alarm From:
Zone 04
Service Faults
The response to a Service Fault condition is programmed by
the installer but is normally limited to the keypad buzzer. To
silence the Service Fault alarm, enter your Access code.
A flashing Service light indicates a new fault condition. The
alarm system cannot be armed whilst a new fault exists. The
Service light will remain flashing until the new fault is
acknowledged, after which it will revert to a steady yellow
and the alarm system can be armed. The Service light will
remain steady until all faults have been cleared.
After a new Service Fault has been acknowledged the
Service light will revert to steady yellow and the alarm
system can be armed. The Service light will remain steady
yellow until all faults have been cleared.
AC Fail and Telephone Line Fault can each have a delay
programmed. The Service light will turn steady yellow
immediately on either of these faults but no Service Fault
Alarm (transmission or audible alarm) will occur unless the
delay expires.
"
If your installer has disabled AC fail acknowledgement
the Service light will flash “rapidly” during an AC fail
condition. The system can be armed without requiring
acknowledgement of this fault.
Acknowledging a New Service Fault
" New service faults can be acknowledged as follows:
System Faults:-
Press Menu/Reset
YES to Arm?
MENU for Options
The keypad will display all Service Faults.
Press or to acknowledge the fault and return to
the normal disarmed state.
NR
Press N2
Enter Access code ????
1
2
3
Line Fault
Press Menu/Reset
Armed
Zones
87654321
Ready
Alarm
Service
Armed
Zones
87654321
Ready
Alarm
Service
View Service Faults
" Standing faults can be viewed as follows:
1. Press the - key followed by the $ key.
2. The keypad will display any Service Faults (see
tables).
3. On completion press the - key.

Table of Contents

Other manuals for Texecom Premier 8SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Premier 8SP and is the answer not in the manual?

Texecom Premier 8SP Specifications

General IconGeneral
BrandTexecom
ModelPremier 8SP
CategoryControl Panel
LanguageEnglish

Related product manuals