Premier 8SP Master User Manual User Functions Menu
INS237 11
Service Faults Displayed on LED Keypads
Light Fault Condition
1 AC Fail
2 Telephone Line Fault
3 2-Wire Smoke Alarm
4
Tamper Inputs:
Press ( to view type, Lights 1 - 3 will light up:
Light 1 = Panel Box Tamper
Light 2 = Auxiliary Tamper
Light 3 = Bell Tamper
5 Date or Time Lost
6
Zone Tamper/Trouble
Press ) to view zone number
7
Keypad Tamper/Removed
Press * to view keypad number
8
Equipment Faults
Press ! to view fault type:
Light 1 = Bell Output Fault
Light 2 = Strobe Output Fault
Light 3 = Reserved
Light 4 = 2-Wire Smoke Sensor Fault
Light 5 = Auxiliary Fuse Failed
Light 6 = Battery Fault
Light 7 = Service Timer/Zone Soak Test Failed
Light 8 = Communication Fault
Service Faults Displayed on LCD Keypads
LCD Fault Condition
!"#$%&'# AC Fail
(&)*#$%+',# Telephone Line Fault
-./0*#!'%1.#2345# 2-Wire Smoke Alarm
6%)*'#7/8#9%.:*1# Panel Box Tamper
!+8&'&%1;#9%.:*1 Auxiliary Tamper
7*''#9%.:*1# Bell Tamper
<%,*=9&.*#(/>># Date or Time Lost
9%.:*1#?/)*#@#AB# Zone Tamper/Trouble
9%.:*1#C*;:%D@#B# Keypad Tamper/Removed
7*''#$%+',# Bell Output Fault
-,1/E*#$%+',# Strobe Output Fault
-./0*#-*)F#$%+',# 2-Wire Smoke Sensor Fault
!+8F#$+>*#$%+',# Auxiliary Fuse Failed
7%,,*1;#$%+',# Battery Fault
-*1G&H*#I*J+&1*D Service Timer/Zone Soak Test Failed
"/.>#$%&'*D# Communication Fault
Anti-code Reset
This feature is normally used in the UK where users are not
permitted to reset the panel following a communicated
alarm. However, the user can reset the panel after entering a
unique remote reset number, which is supplied by their
installer or ARC.
" To perform an Anti-code Reset, proceed as follows:
Quote Code> 4855
Enter Reply>????
YES to Arm?
MENU for Options
The keypad will display a
randomly generated
4-digit Code.
Press N3
Enter Access code ????
1
2
3
Armed
Zones
87654321
Ready
Alarm
Service
Armed
Zones
87654321
Ready
Alarm
Service
Armed
Zones
87654321
Ready
Alarm
Service
Armed
Zones
87654321
Ready
Alarm
Service
Armed
Zones
87654321
Ready
Alarm
Service
Contact your ARC/Installer to obtain a Anti-code Reset
number.
Tel No.__________________________________________
Enter the Anti-code Reset number given to you by your
ARC/Installer .
If the code is accepted, the keypad will sound an
acceptance tone and the system will reset and return to
the normal disarmed state.
????
4
Toggle Chime On and Off
When a zone is enabled for Chime the keypad will generate
a Chime tone every time the zone is violated. This function
allows you to turn the Chime feature on and off.
" To toggle Chime on and off, proceed as follows:
If Chime was off, it will turn on and the keypad will
sound the Chime tone. If Chime was on, it will turn off
and the keypad will sound the acceptance tone.
Enter N4
Enter Access code ????
Armed
Zones
87654321
Ready
Alarm
Service
1
2
3
Premier 8SP
17:30.21 28/04
Armed
Zones
87654321
Ready
Alarm
Service
Press C
YES to Arm?
MENU for Options