Page #7 background imageLoading...
Page #7 background image
Premier Elite Series User Guide
INS555-5 7
Using a Proximity Tag
General Operation
1. A Proximity TAG must be held over the PROX symbol on the keypad.
2. A Proximity TAG will normally work at distances of up to 4cm, however it should be noted that distances can and do vary.
3. Presenting a Proximity TAG to the keypad is NO different to entering a code except that it is a SINGLE action as opposed to a
MULTIPLE action.
4. The control panel will log which User/TAG has been presented.
Programming Proximity TAGS
Programming a Proximity TAG will depend on which type of control panel and what version of software is installed (Your Installation
Company can advise if it is possible to use Tag’s on your system).
Determine your Panel Type
From Day Mode press
followed by 4, the keypad will display the Model and software version. Note which Model you have and
proceed as follows:-
Programming
To assign a Proximity TAG to a User, proceed as follows:
1. Program the User code as normal, this new option will now appear at the end :- ‘Do you want to Add TAG to User?’
2. Press
3. Present the Proximity TAG to the keypad within 10 seconds
4. A confirmation tone will be heard, the TAG is now programmed.
Arming
To Arm the Control Panel, proceed as follows:
1. Present the TAG to the keypad, the display will show ‘Do You Want To Arm System?
2. Present the TAG again (or hold it in place) and the exit will start, leave the building
If Quickarm is enabled the system will start the exit time immediately.
Disarming
To Disarm the Control Panel, proceed as follows:
1. Enter the building Via the designated Entry point (the entry tone will sound)
2. Present the TAG to the keypad, the entry tone will stop, the alarm is now disarmed

Other manuals for Texecom Premier Elite Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Premier Elite Series and is the answer not in the manual?

Texecom Premier Elite Series Specifications

General IconGeneral
Event Log1000 events
ExpandersSupports up to 8 expanders
Wired ZonesUp to 48 wired zones
Wireless ZonesUp to 64 wireless zones
Batteries12V 7Ah
Tamper ProtectionYes
OutputsUp to 8 outputs
Battery BackupYes
CompatibilityCompatible with Texecom accessories
DimensionsVaries depending on model