Speech Dialler Installation Manual
8 INS232-2
Control Panel Connection Table
The table below shows connection details for various alarm control panels:
Trigger Inputs
Control Panel
1
Fire
2
PA
3
Intruder
Trigger
Polarity
+12V 0V
A1 Advantage N/A N/A Bell - -ve Aux + Aux -
ADE Accenta 6 N/A N/A B -ve 13V + 13V -
ADE Concept 6 N/A N/A B -ve 13V + 13V -
ADE Optima 2+ Fire PA Intruder -ve 13V + 13V -
ADE Optima XM N/A N/A B -ve 13V + 13V -
Ademco Infra 6 N/A N/A 3 +ve Aux + Aux -
Ademco Infra 16 1* 2 3 +ve Aux + Aux -
C & K 700L N/A N/A S- -ve Aux + Aux -
CQR Premier 9 FA* PA IA +ve Aux 12V Aux 0V
DA Abacus 6 N/A N/A Bell -ve +12V 0V
DA Abacus 8 N/A N/A Bell -ve +12V 0V
Gardtec 500 Series N/A N/A Bell - -ve Power + Power -
Gardtec 800 Series D1* PA 12Hr -ve 12V 0V
Menvier TS400/TS410 Zone 4 Zone 5 ALM -ve Aux + Aux -
Menvier TS510 N/A OP 2 * OP 1 * +ve Aux + Aux -
Menvier TS690R OP 1 OP 2 OP 3 -ve Aux + Aux -
Menvier Networker Series Digi 1 Digi 2 Digi 3 -ve Aux + Aux -
Pyronix Paragon +/E N/A N/A BA -ve Aux + Aux -
Pyronix Octagon N/A PA ALM -ve Aux + Aux -
Pyronix Conqueror N/A N/A BA -ve Aux + Aux -
Scantronic 9448 N/A COM 2 COM 3 -ve 12V 0V
Scantronic 9452/3/4/5 N/A COM 1 COM 3 -ve 12V 0V
Scantronic 9750/9850 Pin 1 Pin 2 Pin 3 -ve Pin 9 Pin 8
Texecom Veritas 8 Compact N/A N/A B -ve Aux + Aux -
Texecom Veritas 8/R8 N/A N/A B -ve Aux + Aux -
Texecom Veritas R8 Plus Com 1 Com 2 Com 3 -ve Aux + Aux -
Texecom Veritas Excel Com 1 Com 2 Com 3 -ve Aux + Aux -
Texecom Premier 24 O/P 1 * O/P 2 * O/P 3 * -ve Aux + Aux -
Texecom Premier 48/88/168 Digi 1* Digi 2 * Digi 3 * -ve Aux + Aux -
* Control panel output may require programming to the correct function.