EasyManua.ls Logo

ThermoFLUX INTERIO - System Overheating; Smoke; Fire in the Room

ThermoFLUX INTERIO
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
1.7.1 System overheating
If the heating system overheats despite all the elements, it is necessary to
proceed as follows.
Do not open doors on the stove
Turn off the boiler pressing the button
for 3 seconds
Open all heating circuits and switch on
all pumps (stove control does this
automatically)
Leave the pellet stove room and close
the door
Open all available valves on the
radiators / distribution boxes
If the temperature in the system is not decreasing, call the authorized
service center.
1.7.2 Smoke
Flue gases can cause poisoning!
Do not open doors on the stove
Turn off the stove pressing the button
for 3 seconds
Ventilate the room where the stove is
located
Leave the room and close the door
1.7.3 Fire in the room
In case of fire in the room:
Turn off the boiler pressing the
button for 3 seconds
In case of fire use only
extinguishers type AB with
powder.