EasyManua.ls Logo

ThermoFLUX INTERIO - Language Options; STAND by Mode; STAND by Mode with Installed Sensor for Water Temperature

ThermoFLUX INTERIO
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
6.3.4 LANGUAGE OPTIONS
Language settings are adjusted by pressing the SET button,and after that by
pressing of button 5 or 6 we choose option MENU 03-LANGUAGE.
By pressing of the SET button language menu is opened
(italian,english,german,french, croatian...) in which we can choose desired
language by pressing button 1 or 2.
When desired language is choosen, confirmation is to be done by pressing button
SET.
Returning back is done by pressing button 4 (ON/OFF)
6.3.5 STAND BY mode
STAND BY is used in two ways..
In the case that stove shuts down because desired temperature is reached
(set ON ) ,
In the case that stove modulates when desired temperature is reached (set
OFF).
Function STAND BY can be set ON or OFF on following way:
STAND BY mode is activated by pressing button SET, and afterwards by
pressing buttons 5 and 6 we choose desired item in the MENU 04 STAND BY
MODE.
By pressing SET we are opening options ON or OF (choosed by pressing of
buttons 1 or 2, and confirmed by prissing of button SET).
6.3.5.1 STAND BY mode with installed sensor for water temperature
Connection for room thermostat is delivered overbridged, which
means that contact is closed.
1. FUNCTION STAND-BY SET ON
In the case that function STAND-BY is activated (ON), stove will shut down when
desired temperature is reached and above by 2 degrees C, and after 2 minutes of time
pause (set in factory) TON-WAITING COOLING is displayed. If temperature do not
decrease below set temperature during 4 (four) minutes, on display is written TON-
REQUEST WAITING.
When temperature of the water in stove is below set temperature by 2 degrees C,
stove will start again with ignition mode and it will work on set power.

Table of Contents