4.1.1 Switch off main power supply
Be sure to turn off the main power before any work.
4.1.2 Check mechanical connections
Check that all components are properly connected.
Check that all mechanical components are securely attached.
4.1.3 Check hydraulic connections
Check that the circulation pump and the mixing valve are properly
connected.
Check that the safety equipment is properly connected.
After completing the work, fill the system and wait an hour to control
all the connections.
The pellet stove comes with a built-in expansion tank and can only be connected to a
closed heating system.
4.2 Chimney and flue gas pipes
The chimney should be calculated and constructed in accordance with the EN
13384-1 standard.
The venting of flue gas must be done in accordance with all applicable laws including
those related to dimensions of the chimney and materials used for its production. Flue
gas channel should be made of adequate materials, such as steel tubes, with various
sealing.
In any case, materials that could potentially catch fire, e.g. wooden planks, beams,
cloth, should be adequately protected with non-combustible material. For the sake of
parity of dimensions, chimneys that are round in shape of the inner part should have
an advantage over the rectangular-shaped chimneys.
Too small inner zone can cause irregular flow from the stove to the top which could
lead to poor stove performance and excessive exhaust gas production that discharges
the exhaust gas to the environment. Gas flue pipe should be permanently installed and
it would be good to make safety door which would enable the cleaning of inner parts,
especially the horizontal parts.
Smoke pipe should be installed fixed. It would be good to leave safety gates that could
do the interior cleaning, especially in their horizontal parts.
You should avoid as much as possible horizontal mounting parts. Horizontal parts must
have a slope of at least 3% upwards.
Length of the chimney pipes should be minimal and in any case not more than 3
meters.
ALL PARTS OF THE FLUE GASN PIPE NEED TO BE SECURED AND REPLACEABLE
IN ORDER FOR INTERNAL CLEANING. AVOID MULTIPLE HORIZONTAL
DEVIATION AND ANGLES.