EasyManua.ls Logo

Thinky ARV-310 - Specifications

Thinky ARV-310
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Outline and Specifications
ARV-310 2-3
2-2 Specifications
Product Vacuum mixer “Thinky Mixer”
Model ARV-310
Method Vacuum-type, planetary, propeller-less mixing
method
Operating time
setting range
0 sec. – 30 min. (Max. 30 min. run/Setting in the
unit of 1 sec.)
Revolution speed Max. 2,000 rpm (0 rpm and 200 rpm – 2,000
rpm / Increment per 10 rpm)
Rotation speed Max. 1,000 rpm (1/2 of revolution speed)
Standard container
Inner volume: 300 ml and 150 mlMaterial: HDPE
For 300 ml-container: 250 ml, 310 g (net weight)
At ambient
pressure:
For 150 ml-container: 150 ml, 310 g (net weight)
For 300 ml-container: 200 ml, 310 g (net weight)
Max.
mixing
volume
At vacuum
For 150 ml-container: 120 ml, 310 g (net weight)
Vacuum chamber Rotating part vacuum chamber
Vacuum pump
capacity
266 Pa (About 2 Torr), 100 lit./min.
Vacuum pump oil
SAE #10ISO #VG32
Ultimate pressure in
vacuum chamber
660 Pa (About 5 Torr) at use of jER (epicoat)
#828
*)
Ultimate pressure
reaching time
Less than 1 min. to reach 2.66 Pa (About 20
Torr) at use of jER (epicoat) #828
(*
Time for releasing
pressure in vacuum
chamber to ambient
pressure
Less than 20 sec. (Duration of time till air is
released to ambient pressure)
Voltage
Single phase, 100Vac±10%, 50/60 Hz
Supply
power
Consumption
power
At standby: 50 VA, During operation: Max.
1,000 VA (excl. start time)