4. Operation
ARV-310 4-11
This unit has three operation modes with a combination of
rotating/revolving motion and vacuum decompression. Set the
mixing recipes according to operation modes as below shows.
1. Operation by rotating/revolving motion and vacuum
decompression
Set the revolution speed, vacuum decompression
pressure value, processing time.
For details, refer to “1. Setting Procedure for
Rotating/Revolving Motion and Vacuum Decompression”.
2. Operation by rotating/revolving motion only
Set the revolution speed and processing time and turn
OFF the vacuum decompression pressure value (on the
VACUUM indicator).
For details, refer to “2. Setting Procedure for
Rotating/Revolving Motion”.
3. Operation by vacuum decompression only
Turn OFF the revolution speed (on the SPEED
indicator) and the processing time (on TIME indicator)
and set the vacuum decompression pressure value.
For details, refer to “3. Setting Procedure for Vacuum
Decompression”.