12
perceived incorrectly. To prevent the error, you can set
the time term to verify the cell count by the processor.
Normally, 10 minutes are enough to perceive the cell
count correctly. For the battery of larger capacity, you
may extend the time term. But if you set the time term
too long for the battery of smaller capacity, the charge
or discharge process can be finished within the time
term with the erroneous cell count. This may cause the
fatal result. If the processor
recognizes the cell count
incorrectly at the beginning
of ch a rg e o r d isc ha r ge
process, you may extend
the time. Otherwise, you
had better use with the
default value.
This shows the trigger
v o l t a g e f o r a u t o m a t i c
c h a r g e t e r m i n a t i o n o f
NiMH and NiCd battery.
The eff
ective value ranges
from 5 to 20mV per cell. If
the trigger voltage is set
higher, there is a danger
of overcharging the battery; if it is set lower, there is a
possibility of premature termination. Please refer the
technical specification of the battery.
(NiCd default: 12mV, NiMH default: 7mV)
NiMH Sensitivity
D.Peak Default
Display
Display
- +
DEC INC
DEC INC
NiCd Sensitivity
D.Peak Default
Display
Display
- +
DEC INC
DEC INC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thunder T6 and is the answer not in the manual?

Thunder T6 Specifications

General IconGeneral
BrandThunder
ModelT6
CategoryBattery Charger
LanguageEnglish

Related product manuals