17
of the battery pack to be charged. To do this, the battery
pack being charged should have the individual cell
connector. And connect it to the individual port at the
right side of charger with a suitable connection cable
that fits with your battery pack. And also, you need to
connect the battery output plug to the output of charger.
In this mode, the charging process will be different
from ordinary charging mode. The internal processor of
the charger will monitor the voltages of each cell of the
battery pack and controls the charging current that is
feeding to each cell to normalize the voltage.
The value on the left side
of second line sets a charge
current and the value on
the right side of second
line sets the voltage of the
battery pack.
After setting the current
and voltage press
Start/
Enter
key for more than 3 seconds to start the process.
This shows the number
of cells you set up and the
processo r detects. R:
shows the number of cells
found by the charger and
“S:” is the number of cells
se l e c te d b y y o u a t t h e
previous screen. If both numbers are identical you can
start charging by press
Start/Enter
button. If not,
LiPo BALANCE
2.0A 11.1V(3S)
Display
- +
DEC INC
Display
- +
DEC INC
Batt type
Stop
Start
Enter
'>3 seconds'
R:3 SER S:3SER
CONFIRM(ENTER)
Display
Display
Start
Enter