Owner’s Manual
E2010 THYSSENKRUPP ELEVATOR Printed in USA February, 2010
Door Protection-5
The detectors have AMP connectors preinstalled which fit
onto the pin headers provided in the 280.
The Memco power supply provides:
S a regulated DC supply for the 640 detectors
S a relay output for connection to the door re-open circuit
S an audible tone when the light-curtain is broken (Note - this
can be disabled)
S Model 280 is powered from an AC supply (115V)
The Model 280 is factory-set for “fail-safe” operation using
standard PNP -N/C 640 detectors. However switches are
provided to allow detectors with other transistor configura-
tions to be used.
Direct Connection
The connectors are keyed and can only be installed in the
correct position. If forced incorrectly by the installer the
locking tab will be broken and can cause possible damage to
the detectors.
The 640 can be connected directly to the lift-controller or
door-operator if it has a suitable power supply and ”door
reopen” circuit. A special adaptor c able is required for
Thyssen lifts. The power supply must be regulated DC
(11-30V) with no transients. The door reopen circuit must
accept a transistor drive and the current must never exceed
100mA.
Contact Memco to discuss direct connection
in more detail.
Figure 9 - Specifications
As a result of our policy of continual improvement, the information in this document is subject to change
without notice and it is intended only as general guidance on product performance and suitability. This
information shall not form part of any contract
SPECIFICATIONS - Model 640 180/TK
Detector size: 1
9
/
16
”x
3
/
4
” x 6’ 10
11
/
16
”
Det ecto r cable : 16’ 4” integr a ted detect or cable
Fixing kit: For Standard or Leading Edge Ver sions
Distance between bottom beam
& bottom of housing:
11
/
16
”
Distance betw een top beam
& bottom of housing: 6’
Range: 9’ 10”
Number of diodes per detector: 32
Distance between Diodes 2
5
/
16
”
Number of beams: 154 when detectors are typically more than 23
5
/
8
”apart,
94 when detectors are typically less than 23
5
/
8
”apart,
72 when detectors are typically less than 11
13
/
16
”apart
Input Voltage: 11-30V DC max
Indicators: 2 red LEDs on TX
Operating temperature r ange: -10°Cto55°C BS2011 Part2.1:N1985
Temperature storage: -20°Cto55°C BS2011:Part2.1Bd
EMC Specifications Emission to EN12015, Immunity to EN12016
IP Rating IP54
Light i mmunity:
100,000 lux