MEP S.p.A.
10--10
164
Use and maintenance manual TIGER 370 CNC--MR
EMERGENCY
CODE ERROR
SHORT CIRCUIT XX
PRESS RESET
This message is displayed each time the controller software transmits an error, it is
identified as (XX). Here follows a list of error codes which may occur during work-
ing.
0 = INCORRECT RESET OR INTERRUPTS
1 = DIGITAL INPUTS CARD 3 UNSTABLE
2 = DIGITAL INPUTS CARD 4 UNSTABLE
3 = NO STATUS OR SCREEN
4 = DIGITAL INPUTS CARD 1 UNSTABLE
5 = DIGITAL INPUTS CARD 2 UNSTABLE
6 = ANALOGUE INPUT BLADE TENSION (#9) UNSTABLE
7 = INP. ANALOGIC AXIS BLADE MOTOR (#3,4) UNSTABLE
8 = INP.ANALOGIC POWER TABLE CENTRE HEAD (#6) UNSTAB.
9 = OUTS 1st AND 2nd OUTS REQUEST SPEED. SIMULT.
10 = REQ. OUTS 1st AND CEN. STAR 2nd SPEED. SIMULT.
11 =REQ.OUTS1st,CEN.STARAND2ndSPEED.SIMULT.
12 = EEPROM UNAVAILABLE
13 = IUV FAILURE
14 = TEST R AM FAILED
15 = TEST ROM FAILED
16 = UNDEFINED EMERGENCY
17 = NO CUTTING CYCLE PHASE
18 = INP.ANALOGIC POWER TABLE CENTRE. HEAD (#6) UNSTAB.
" Press RESET to restore manual command control