PK-232 – MBX OPERATING MANUAL COMMAND SUMMARY
4/91 A-37 162
o If another disconnect command is entered while your PK-232 is trying to disconnect, your
PK-232 will instantly switch to the disconnected state.
DISPlay [class] Immediate Command
Mode: Command Host: Not Supported
Parameters: class - Optional parameter identifier, one of the following:
(A)sync display asynchronous port parameters
(B)BS display AMTOR and Packet MailDrop parameters
(C)haracter display special characters
(F)ax display Facsimile parameters
(I)d display ID parameters
(L)ink display link parameters
(M)onitor display monitor parameters
(R)TTY display RTTY parameters
(T)iming display timing parameters
(Z) display the entire command/parameter list
DISPLAY is an immediate command. When DISPLAY is typed without a parameter, the PK-232 re-
sponds with a short list of often used parameters.
(See also DISPLAY A,B,C,F,I,L,M,R,T,Z)
Connect Link state is: DISCONNECTED
Opmode PAcket
FRack 5 (5 sec.)
HBaud 1200
MAXframe 4
Monitor 4 (UA DM C D I UI)
MYcall PK232
MYSelcal none
PACLen 128
RBaud 45
TXdelay 30 (300 msec.)
Vhf ON
WIdeshft OFF
You can display subgroups of related system parameters by specifying the optional class parame-
ter. For example, to display the AMTOR and Packet MailDrop parameters type:
cmd:disp b
3Rdparty OFF
FREe 18340
KILONFWD ON
LAstmsg 0
MAildrop OFF
MDMon OFF
MDPrompt Subject:/Enter message, ^Z (CTRL-Z) or /EX to end
MMsg OFF
MTExt Welcome to my AEA PK-232M maildrop.
Type H for help.
MYMail none
TMail OFF
TMPrompt GA subj/GA msg, '/EX' to end.