8 Performance Series 450e
Description of unit Starting operation
3.5 Technical data
Voltage: 110VoltAC,50/60Hz
Max. current consumption: 9.5A@110VAC
Power cord: 3 x 1.5 mm
2
– 6 m
Acceptance capacity: 900 Watt
Max. operating pressure: 214bar(21.4MPa)
Volume ow at 12 MPa
(120 bar) with water: 1.62 l/min
Max tip size: 0.021 inch – 0.53 mm
Max. temperature of the
coating material: 43°C
Max viscosity: 20.000 MPa·s
Weight: 15.2 kg
Special high-pressure hose:6,35mm,15m-18NPSM
Dimensions (L X W X H): 480 x 360 x 405 mm
Vibration: Spray gun does not
exceed 2.5m/s
2
Max sound pressure level: 80dB(A)*
* Placeofmeasuring:1mindistancefromtheunitand1.6
mabovetheoor,12MPa(120bar)operatingpressure,
reverberantoor.
3.6 Transportation in vehicle
Secure the unit with a suitable fastening.
4. Starting operation
4.1 High-pressure hose, spray gun and
separating oil
1. Screwthepressuregauge(1)tothecoatingmaterial
outlet(Fig.2,Item2).
2. Screwthehigh-pressurehose(3)tothecoatingmaterial
outletonthepressuregauge(Fig.2,Item4).
3. Screwthespraygun(5)withtheselectedtipontothe
high-pressure hose.
4. Tightentheunionnutsatthehigh-pressurehosesrmly
so that coating material does not leak.
5. FilltheoilcupwithPistonLube(Fig.3).Donotusetoo
much Piston Lube, i.e. ensure that no Piston Lube drips
into the coating material container.
Piston Lube prevents increased wear and tear to
the packings.
4.2 Connection to the mains network
The unit must be connected to an appropriately-
grounded safety outlet.
Before connecting the unit to the mains supply, ensure that the
linevoltagematchesthatspeciedontheunit’sratingplate.
4.3 Cleaning preserving agent when starting-
up of operation initially
1. Depending on the model, swivel or immerse the suction
tube(Fig.4Item2)orthesuctionhoseandreturnhose(1)
into a container with a suitable cleaning agent.
2. Turnthepressurecontrolknobcounterclockwise(3)to
minimum pressure.
3. Openthereliefvalve(4),valvepositionPRIME
(kcirculation).
4. Switchtheunit(5)ON.
5. Wait until the cleaning agent exudes from the return hose.
6. Closethereliefvalve,valvepositionSPRAY(pspray).
7. Pull the trigger of the spray gun.
8. Spray the cleaning agent from the unit into an open
collecting container.