35
Production tightening mode
1. Setting items
Setting items Display
Default
Alternative selection
1
Tightening mode SEL
MODE-SMODE-P
2
Measurement Unit USEL Nm
kgfcm/kgfm/lbf
in/lbfft
3
Tightening torque SE
0
Below max torque
4
Tightening torque upper
limit
SE_
0
Below max torque
5
Snug torque Sng
0
Below max torque
6
1
st
tightening angle An1
0
Bellow 999
7
1
st
tightening angle upper
limit
A1_
0
Below 999
8
2
nd
tightening angle An2
0
Below 999
9
2
nd
tightening angle upper
limit
A2_
0
Below 999
10
3
rd
tightening angle An3
0
Below 999
11
3
rd
tightening angle upper
limit
A3_
0
Below 999
12
Spindle number
1
Below 999
13
NG setting ng
NG_RES
AL_RES
14
Tightening direction tUrn
CW
CCW
15
Auto memory/reset timer Ar
0.0
0.0, 0.1 - 5.0
16
Buzzer bU
ON
OFF
17
Auto power off timer PoFF
3min
10min, 30min, NONE
18
External output mode do
PC
PRN
19
Baud rate bpS
9600
2400, 4800, 19200
20
Data length dL
8bit
8bit
21
Parity Prt
Even
NoneOdd
22
Default dFLt
DFLT-N
DFLT-Y
23
Time (h/m/s) rtC1
None
―――
24
Date (y/m/d) rtC2
None
―――
* Default function (21) does not initialize the tightening mode and time and date.