DIGITAL TORQUE WRENCH TESTER DOTE4-G
8-3. Operation with Communication Command
Setting of DOTE4-G can be changed by communication command from an external device.
DOTE4 executes the command and sends back response command to the external device.
(1) Communication commands
All commands are ASCII code
Append CRLF in the end of command
(2) Communication example
• In case of switching upper limit setting (A)
• In case of setting upper limit at 50.00 and lower limit at 40.00
Command Motion
AT219 ,* Switch registered upper/lower limit. * must be A:0,B:1,C:3…J.9
AT037,******,****** Register upper limit and lower limit at the same time.
* must be torque value in 6 digits including decimal point.
AT023,******* Register 7-digit alphanumeric.
* must be upper case alphabet or number.
Registered 7-digit alphanumeric is appended to measurement data.