Troubleshooting
3D-MC² Quick Reference Guide
A-24
Problem
Blade is moving too fast. The blade seems to move
too fast in Control Mode. The Grade Indicator skips
through on-grade.
Causes Solutions
The Valve Gain
setting is too high.
Decrease the Valve Gain setting,
which will cause the hydraulics
to respond slower.
Check which side control is fast
before adjusting the Valve Gain.
Remember that the lower
number setting slows down the
response.
Problem
Blade reacts, but does not reach On Grade
Causes Solutions
Valve Offsets are
too small.
Assume that Valve Offsets are
too small, and perform a Valve
Offsets Calibration.
Problem
Blade reacts, but overshoots around On Grade
Causes Solutions
Valve offsets are
too large.
Assume that Valve Offsets are
too large, and perform a Valve
Offsets Calibration.