OPHTHALMIC UNIT
IS-100
Rev. 6 - November 2019Rev. 6 - November 2019
3-2
USER MANUAL
3.1. CHARACTERISTICS
3.1.1. Unit IS-100
CHARACTERISTIC VALUE
Power supply 110-240 VAC / 50-60 Hz
Consumption 850 VA
Electricalclassication Class I / Type B
Maximumpowerofthersttabletop
instrument
160 VA
Maximum power of the second tabletop
instrument
150 VA
Slow start system (bulb protection) Yes
Unit lamp output 24 VDC - 9 W
General protection (junction box)
220 V: 2 x F4A/L/250 V
Ø5 x 20 mm
110 V: 2 x F8A/L/250 V
Ø5 x 20 mm
Net weight 120 kg
Gross weight 140 kg
Maximum load on the tabletop 35 kg
Maximum acceptable load for support 3
(phoropter)
10.3 kg
Maximum acceptable load for support 3 (light,
screen, etc.)
6 kg