PROGATE User manual V-2022-09-20 5 | EN
1.2 Used definitions and terms
Contains information about alarms that are currently active on the system or information about alarms that have been
raised and then resolved on the system. This log can be useful in analyzing problems and trends in the system.
A process of enabling/disabling system's security.
It is a person whose mobile phone’s number is entered in PROGATE module. Several authorized users with the same
rights may be entered into the module.
The secondary power source of the system. In case of a main power failure, the backup battery will take over.
If enabled, the siren/bell indicates the completed system arming and disarming process (except the arming in STAY mode).
After the system is successfully armed, the siren/bell will emit 2 short beeps and 1 long beep after the system is disarmed.
By default, the parameter is disabled.
Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone. If a bypassed
zone is violated or restored during exit/entry delay, or when then system is armed, it will be ignored. The zone will remain
bypassed until the system is disarmed. Zones can only be bypassed and activated when the system is not armed.
Negative power supply terminal.
Programming of the settings, which will define the operation of the item. For example, user's telephone numbers, set-up of
periodicity for sending SMS message, input names etc.
Central monitoring station
The system makes a call to the number specified.
When using Configuration tool software, you may monitor system inputs/ outputs, view changes of peripheral devices,
instantly configure necessary options, for example, enabling/disabling PGM outputs, etc.
The system initiates the entry delay countdown if a Delay type zone is violated. The countdown is indicated by short beeps
emitted by keypad buzzer and by steady beep emitted by system's buzzer. The indication is intended to advise the user
that the system should be disarmed. If the system is disarmed before the entry delay expires, no alarm will be caused.
(End of line resistor) input type with resistor.
The information that the user receives.
A list of system events that is uploaded from the device‘s memory to the configuration software for further analysis. The
system logs all information about system configuration, system actions and info messages.
A period of time intended for user to leave the secured area. The system begins the countdown after the arming process
initiation.
A specific problem or error that prevents the system from working properly. The system comes equipped with self-
diagnostic feature allowing to indicate the presence of any system fault and send SMS text message notification to the
listed user phone number.
A unique 64-bit ID code containing chip enclosed in a stainless steel tab usually implemented in a small plastic holder. The
module supports up to 800 iButton keys each holding a unique identity code (ID), which is used for system arming and
disarming.
a person provided with INST (installer's) password
Allows to carry out system arming/ disarming as well as minor system configuration and control
It is a switch that passes current until actuated.
It is a switch that must be actuated to pass current.
Provides the following information on alarm system: date & time, status (armed/disarmed), GSM signal strength, mains
power supply status, temperature value measured by primary and secondary temperature sensors (if any).
Is that it weakly "pulls" the voltage of the wire it is connected to towards +V (or whatever voltage represents a logic "high").
A PGM output is a programmable output that toggles to its set up state when a specific event has occurred in the system
or if the user has initiated the PGM output state change manually.
Sets period of time defining how often the module sends ping data packet to the server.
ARM/DISARM, test, resetting of the system.
System can re-sent all incoming SMS messages to the specified users. It is useful if the GSM operator of the inserted SIM
card sends some useful information (SIM card validation or payment account status and etc.) or it is necessary to monitor
all incoming SMS messages by specified user.
It is a person being aware USER password.
Detection devices such as motion detectors and door contacts are connected to the alarm system’s zone terminals.
Zone status is a position of a certain zone being enabled or disabled. Meanwhile, zone state points out the condition of a
certain zone, which can either be violated (i.e. In case of alarm) or restored.
Positive power supply terminal.