PROGATE User manual V-2022-09-20 22 | EN
9. Write configuration by pressing [Write]
In order to control big power alternating current equipment, it is comfortable to use solid state relays.
6 INPUTS
The module PROGATE has:
2 analog inputs (In1, .In2 (0-30V)) for analog sensors connection. Or can be used as security system‘s zones with selectable type:
NC/NO/EOL/EOL+TAMPER.
2 programmable analog inputs (I/O1, I/O2(0-30V) for analog sensors control or using as security system‘s zone with selectable type:
NC/NO/EOL/EOL+TAMPER
Wiegand interface, RFID reader, Keyboard.
1 programmable digital inputs (D1(Max voltage 3.3V)) used for:
o Dallas 1-Wire Bus. To connect temperature sensors DS18b20 or iButton key DS1990A,
o Aosong 1-Wire bus Humidity Sensor AM2302, DHT22, AM2305, AM2306,
6.1 Input / zones wiring EOL NO NC
The module PROGATE has:
In1, In2, I/O1, I/O2 Can be used as inputs to detect Gate position or security system‘s zones with selectable type: NC/NO/EOL/EOL+TAMPER.
It is recommended to use standard motion, fire, and glass breaking sensors. For powering of sensors we recommend to use standard 6-8
wires cable for, designed for installation of security system.
Connect sensors to module the as is shown in connection diagrams below
Set the required parameters
Write configuration by pressing [Write] button
Figure 23NC Contacts, No EOL
Figure 26NC With EOL Wire Fault
Recognition
All inputs has pull up resistors 10k
Refer to: Outputs. Bell & PGM programming
Refer to: Zones programming