7.9 RT Testing & Monitoring. Hardware.
RT Testing & Monitoring > Hardware
The Hardware monitoring window let you see real time input, output actions and GSM information. Thus
it would be easier to evaluate whether the input, output actions, registration to the network operates as
appropriate.
Figure 53 RT Testing Monitoring> Hardware window
Pressing Start Monitoring button starts the monitoring of the module.
Pressing Stop Monitoring button stops the monitoring of the module.
IMEI number of GSM modem available in the module
ICCID (Integrated Circuit Card Identifier) - A SIM card contains its unique serial number (ICCID).
ICCIDs are stored in the SIM cards and are also printed on the SIM card.
If note READY is visible, it means that SIM card is fully functioning. Otherwise, check whether PIN
code request is off or replace SIM card.
Signal strength of GSM communication
State of GSM modem registration to GSM network.
SMS Service Centre Address
SMS center number. This number should be checked if it is correct. If this number is incorrect. SMS
messaging may be impossible. This number may be changed after inserting SIM card into any mobile
phone.
Power supply voltage. Nearby number is value of ADC voltage. When multiplying this number by the
coefficient Fig. 32, voltage value (V) will be achieved.
System voltage OK/Trouble
Real time clock OK/Trouble
Indicates the time of the module RTC
By pressing this button real time clock of the module will be set.
In1…In4 is the indicated input ADC and voltage value V.
I/O1…I/O2 is the indicated voltage ADC value and current ADC value mA.
Check box nearby the digital inputs D1…D3 (I/O) means that the input has ‘0’ or ‘1’ state.
Check box nearby the zone expansion module BUS (I/O) means that the input has ‘0’ or ‘1’ state.
Checked box nearby the appropriate output Out1…Out4 means that this output currently has ‘0’ or ‘1’
state. The output could be activated by pressing On/Off button
Checked box nearby the appropriate input/output I/O1…I/O2 means that this input/output currently has
‘0’ or ‘1’ state. The output could be activated by pressing On/Off button
Checked check box nearby the digital outputs D1…D3 (I/O) means that the output currently has ‘0’ or
‘1’ state.