7.10 RT Testing & Monitoring Security Alarm Panel/ Access
RT Testing & Monitoring > Security Alarm Panel/ Access
The Security Alarm Panel/ Access window let you see real time zones states: is zone
alarmed, bypassed, forced etc. This window it let you change system state: disarm, arm,
sleep, and stay. This window let you look to access control area also.
If checked and the color is red the zone is alarmed
If checked and the color is red alarm shutdown for the zone is activated. Allowable number of the
same alarm events is reached and the same events will not be reported.
If checked and the color is red, the zone is bypassed.
If checked and the color is red, the zone is forced
If checked and the color is red, the zone is tampered.
If checked and the color is red tamper shutdown for the zone is activated. Allowable number of the
same tamper shutdown events is reached and the same events will not be reported.
Indication that at the moment the module is in waiting ARM, ARM, DISARM, SLEEP or STAY mode
After pressing the button DISARM, disarm mode should be entered
After pressing the button ARM, arm mode should be entered
After pressing the button SLEEP, sleep mode should be entered
After pressing the button STAY, arm mode should be entered
If the checkbox is checked and the color is red the trouble with system voltage is indicating. If color
is green, there is no trouble with system voltage.
If the checkbox is checked and the color is red RTC clock is not set. If color is green, RTC clock is
set.
Real time and date is indicating.
The number of iButton Maxim iButton key DS1990A - 64 Bit ID code that is arming the system.
The number of users phone that is calling to the module’s SIM.
The number of Wiegand RFID Key Card that is arming the system.
Figure 54 Explanation of every field in "Security Alarm Panel/ Access" window
GPRS/ IP/ TCP/ UDP details must be configured before TCP/IP Remote control will be set
It was discussed in Error! Reference source not found.
7.10.1 TCP/ IP Remote Control
GSM Communication > SERA Cloud Service
The TCP/ IP Remote Control window let you set basic TCP IP remote control
settings and enable or disable remote communication.
Check the particular checkbox to enable remote control/configure module over internet.
IP address xxx.xxx.xxx or domain name of remote control server.