PROGATE User manual V-2022-09-20 29 | EN
Restore Report Enabled=
Report R
The system will report restore event and log it to the event buffer
The system will detect a tamper condition with one or more sensors on the system
The system will allow zones to be Manually Bypassed.
Shutdown if max alarm
count= Shutdown
The system will stop generating alarms once the max alarm count Limit is reached. It resets every time
the system will be armed.
Only force zones can be bypassed when the module is Force armed. Fire Zones cannot be Force Zones.
determines which output will be activated
Figure 41Explanation of every field in "Zones" window
7.5 Outputs. Bell & PGM programming
Figure 42The example of Outputs (PGM) window
Output Location in
Hardware
The outputs hardware location.
21
23
25
27
29
31
33
35
22
24
26
28
30
32
34
36
Selection of output operation mode.
Output for connection of audible sounder (siren). After the alarm system
actuation a continuous or pulse (fire) signal is generated.
Output for buzzer connection. After the alarm system activated a pulse signal is
generated within Exit Delay time, and continuous signal - within Entry Delay time
or when the alarm system is disturbed. When the alarm system is turned off,
operates like keyboard buzzer.
Output for connection of light indicator. When the alarm system is on, a
continuous signals generated, and if the alarm system is disturbed - pulse
signal. Signal is terminated by turning off the alarm system.
Output for connection of light indicator of the alarm system status. Within Exit
Delay time a pulse signal is generated, and when the alarm system activated –
continuous. Signal is terminated by turning off the alarm system.
Output for connection of light indicator of input statuses. If all zones are clear
(none violated), a continuous signal is generated.
Remote control by call mode is enabled. Output designed for connection of
electrical devices which will be controlled by SMS message or phone call
Output for connection of indicator about control panel supply from alternating
current.
Output for connection of indicator about control panel supply from battery.
Output for connection of light indicator of the alarm system status. When the
alarm system is on a continuous signal is generated.
Output for connection of light indicator showing alarm status of the alarm
system. After the alarm system actuation a continuous signal is generated.
Output where a continuous signal is generated when communication with
primary channel was lost.
33 Lost secondary channel
Output where a continuous signal is generated when communication with
secondary channel was lost.