EasyManua.ls Logo

Topkodas PROGATE - Zone Programming Details

Topkodas PROGATE
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROGATE User manual V-2022-09-20 27 | EN
7.4 Zones programming
Detection devices such as motion detectors and door contacts could be connected to the module’s zone terminals. Once connected, the associated
zone’s parameters must be configured.
PROGATE comes equipped with 2 on-board wired zones and 2 programmable I/O inputs.
Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone. If a bypassed zone is violated or
restored during exit/entry delay, or when then system is armed, it will be ignored.
Stay mode allows the user to arm and disarm the alarm system without leaving the secured area. If the zones with Stay attribute enabled are
violated when the system is STAY-armed, no alarm will be caused. Typically, this feature is used when arming the system at home before going to bed.
The system can be STAY-armed under the following conditions: If a Delay-type zone is NOT violated during exit delay and a zone (-s) with Stay
attribute enabled exists, the system will arm in Stay mode. When arming the system in Stay mode under this condition, one of the available arming methods
must be used that provide exit delay.
The difference between stay and sleep zone types: “stay” zone type has delay zone timeout, in “sleep” zone type delay zone becomes
instant
The system will NOT activate siren and keypad buzzer only when Instant, Silent zone types is violated.
Any Delay type zone will operate as Instant type zone when the system is armed in the Stay mode. When the system is fully armed, the
Delay type zone will operate normally.
If the zone is not used, it must be disabled.
The tamper circuit is a single closed loop such that a break in the loop at any point will cause a tamper alarm regardless of the system status
armed or disarmed. During the tamper alarm, the system will activate the siren/bell and the keypad buzzer and send the SMS text message to the listed
user phone number. The system will cause tamper alarm under the following conditions: If the enclosure of a detection device, siren/bell, metal cabinet or
keypad is opened, the physical tamper switch will be triggered. If needed to get tamper alarms, the field near “Tamper Enabled”, should be marked. In that
case, all tampers and tamper alarm notification by SMS text message is enabled.
The system will NOT cause any tamper alarm regarding the physical tamper violation if the associated zone is disabled.
The figure below shows an example of zone operation with a 3-time alarm event limit:
- Zone alarm is generated 3 times.
- After 3 alarm events the zone is blocked (bypassed) till Event Repeat Timeout will end.
- After Event Repeat Timeout zone will activated again.
Figure 39the explanation of Zone Speed, Max Alarm Count, and Event Repeat Timeout

Table of Contents

Other manuals for Topkodas PROGATE