12
Outswing - Low Energy 8 - 10 lbs Commissioning
Requirements
1. Shaft should be secured into drive unit during mechanical installation.
2. Refer to page 22 to adjust open door stop.
3. Determine system values for your application based on the illustrations on page 10.
Commissioning
Commissioning Example: (3) = 36” door width, (1) = 0-2” reveal, (1) = Standard outswing Arm 11 3/8.
3 1 1
Enter Country Code 7 1: (Read Enre Step BEFORE aempng to enter Country Code)
Press & Hold programming buon, Release aer 7 Green flashes then immediately Press & Release
programming
buon aer 1 Yellow flash.
Programming is complete - for further programming enhancements refer to page 23 or Programming Tables
PERFORM
THIS STEP WHILE LOOKING AT BOTH GREEN & YELLOW LEDS.
Press & Hold Programming Button, Release after 1 Green LED Flash. The operator will make 1 beep and immediately
begin to flash the Yellow LED.
WHILE LOOKING AT THE YELLOW LED, WAIT FOR THE OPERATOR TO BEEP 1X, then after 3 yellow flashes, Press & Release
Programming Button
WHILE LOOKING AT THE YELLOW LED, WAIT FOR THE OPERATOR TO BEEP 2X, then after 1 yellow flashes, Press & Release
Programming Button
WHILE LOOKING AT THE YELLOW LED, WAIT FOR THE OPERATOR TO BEEP 3X, then after 1 yellow flashes, Press & Release
Programming Button
MADE AN ERROR DON’T WORRY: To start over Disconnect Power for 10 seconds, Reconnect Power, then Press & Hold
Programming Button and Release after 5 Green LED Flashes.
PAUSE
PAUSE
PAUSE
The operator will open 20 degrees stop and beep 2x. Press & Release programming button.
The operator will slowly close and beep 2x, next it will slowly fully open and beep 2x, then close
(beep 1x) followed by 5 beeps, and will cycle fully open & close at normal speed.