6 Maintenance
The system was tested and approved by an expert before initial commissioning. The manufacturer
recommends that you conclude a service contract in order to maintain the value of your system for as
long as possible as well as to ensure the system operates reliably and safely for a long time.
Only genuine TORMAX spare part should be used. The manufacturer accepts no liability if you fail
to observe this requirement. Original spare parts and original accessories guarantee the safety of
use in accordance with norm EN 16005.
The following maintenance work must be carried out:
6.1 Cleaning
Warning
Closing doors can crush – danger!
Trapped limbs can lead to serious injury.
• ThesystemmustonlybecleanedinoperatingmodeOFF,OPENorManualOperation.
• Cleancasingparts,theuserinterfaceanddoorleaveswithadampclothanda
commercial cleaner.
6.2 Functional Checks
The operator must check the function and safety devices of the automatic sliding door at least
every 3 months. This will ensure that faults or hazardous changes in the system are detected at an
earlystage.Seesection7.2“Check-listforFunctionalChecks”foritemstobechecked.
You should arrange for any defects detected during the routine checks to be rectified immediately by a
TORMAX dealer (see the last page of this Manual for the address).
Warning
Potential switching malfunction in the automatic sliding door.
Potential hazards – injury caused by impact or crushing.
6.3 Maintenance and Testing
Maintenance and testing should only be carried out by a trained specialist following the manufacturer’s
instructions.
Maintenance Interval
The maintenance interval depends on the frequency of use but the system must be maintained at
least once per year.
Scope of the Maintenance Work
The content of the maintenance work is specified by the manufacturer in an inspection list.
System Test Book
The test findings are recorded after the test in the system test book. The operator must keep it in a safe
place.