17
MAINTENANCE
Vacuum and Water Recovery System
NOTE: A dirty or clogged filter will greatly reduce
suction and ability of machine to recover water.
Inspect vacuum filter after each use as follows:
1. Disconnect hose.
2. Turn the two cam-shaped thumb locks.
3. Remove filler assembly.
4. Remove foam filter and rinse with clean water.
5. Drain and flush tanks with clean water.
6. Leave filter assembly out of tank to allow
system to dry when not in use.
A liquid shutoff is built into the filter system to prevent overfilling
tank.
Solution and Recovery (Vacuum) Tanks
Draining Recovery (Vacuum) Tank:
1. Lift drain hose and remove from hook.
2. Insert end of hose into large pail or drain area.
3. Push ball to the side and drain. (Do not remove ball from
hose.)
4. For more extensive cleaning of tank, loosen two thumb nuts
and remove cover. Flush out tank with clean water as necessary.