HighViscosityIndex/LowPourPointAntiwear
HydraulicFluid,ISOVG46
MaterialProperties:
Viscosity,ASTMD445cSt@40°C44to48
cSt@100°C9.1to9.8
ViscosityIndexASTM
D2270
140to160
PourPoint,ASTMD97-34°Fto-49°F
IndustrySpecications:
VickersI-286-S(QualityLevel),VickersM-2950-S
(QualityLevel),DenisonHF-0
Note:Manyhydraulicuidsarealmostcolorless,
makingitdifculttospotleaks.Areddyeadditivefor
thehydraulicsystemoilisavailablein2/3oz.(20ml)
bottles.Onebottleissufcientfor4-6gal(15-221)of
hydraulicoil.Orderpartnumber44-2500fromyour
authorizedTorodistributor.
BiodegradableHydraulicFluid-Mobil224H
ToroBiodegradableHydraulicFluid
(Availablein5gallonpailsor55gallondrums.Seeparts
catalogorT orodistributorforpartnumbers.)
Alternateuid:MobilEAL224H
Thisisvegetable-oilbasedbiodegradableoiltestedand
approvedbyToroforthismodel.Thisuidisnotas
resistanttohightemperaturesasstandarduid,somake
suretofollowrecommendeduidchangeintervalswith
thisuid.Contaminationbymineral-basedhydraulic
uidswillchangethebiodegradabilityandtoxicityof
thisoil.Whenchangingfromstandarduidtothe
biodegradabletype,becertaintofollowtheapproved
ushingprocedure.ContactyourlocalToroDistributor
fordetails.
1.Cleantheareaaroundthehydraulicoilreservoircap
topreventdebrisfromenteringtank(
Figure12).
Figure12
1.Oilreservoircap
2.Removethecapfromthereservoir.
3.Checktheoillevelinthereservoir.Theoillevel
shouldbeuptothetopoftheconepointonthe
tankscreen.
4.Iftheuidlevelislow,slowlyllthereservoir
withtheappropriatehydraulicuiduntilthelevel
reachestheneckeddownareaonthedipstick.Do
notoverll.
5.Installthereservoircap.
Important:Topreventsystemcontamination,
cleanthetopofthehydraulicoilcontainers
beforepuncturing.Ensurethatthepourspout
andfunnelareclean.
CheckingtheTirePressure
ServiceInterval:Beforeeachuseordaily
Checkthetirepressurebeforeoperatingthemachine
(Figure13).Thecorrectairpressureinthefrontand
reartiresare:
•forTreadedtires4-6psi(0.3-0.4bar)
•forSmoothtires8-10psi(0.5-0.7bar)
Figure13
1.Valvestem2.Lugnut
TorquetheWheelLugNuts
ServiceInterval:Aftertherst8hours
Every100hours
Initially,torquethewheellugsaftertherst8hoursof
operation;thereafter,torquethenutsafterevery100
operatinghours.Torquethelugsnutsto45-55ft-lb
(61-75N⋅m).
StartingandStoppingthe
Engine
1.Removeyourfootfromthetractionpedal,make
surethatthepedalisintheneutralposition,and
engagetheparkingbrake.
17