ServicingtheBattery
ServiceInterval:Every250hours
DANGER
Batteryelectrolytecontainssulfuricacidwhichisa
deadlypoisonandcausessevereburns.
Donotdrinkelectrolyteandavoidcontactwith
skin,eyes,orclothing.Wearsafetyglassesto
shieldyoureyesandrubberglovestoprotect
yourhands.
Fillthebatterywherecleanwaterisalways
availableforushingtheskin.
WARNING
Chargingthebatteryproducesgassesthatcan
explode.
Neversmokenearthebatteryandkeepsparksand
amesawayfromit.
Checkthebatterycondition.Keeptheterminalsand
theentirebatterycasecleanbecauseadirtybatterywill
dischargeslowly.Tocleanthebattery,washtheentire
casewithasolutionofbakingsodaandwater.Rinseit
withclearwater.
DriveSystem
Maintenance
ChangingtheTransmission
OilFilter
ServiceInterval:Aftertherst50hours
Every500hours
G018091
1
Figure39
Righthandsideofmachine
1.Transmissionoillter
1.Unscrewandremovethebottomofthetransmission
oillterhousing.
2.Withdrawthelterelementanddiscard.
3.Retanewlterelement(Partno.924709).
4.Installthehousing.
ChangingtheHydraulicReturn
Filter
ServiceInterval:Aftertherst50hours
Every500hours
1.Removethereturnlter.
2.Wipeoilontothenewreturnltergasket.
3.Installthenewreturnltertothemachine.