EasyManua.ls Logo

Toro 41177 - Cleaning; Cleaning the Flowmeter; Cleaning the Suction Strainer

Toro 41177
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cleaning
CleaningtheFlowmeter
ServiceInterval:Every400hours/Yearly(whichever
comesrst)
Occasionally,theowmetermayneedtobecleanedto
removeanobstruction.
Note:Makesurethepumpisoffwhenperforming
thisprocedure.
1.Disconnecttheowmeterwirefromwiringharness.
2.Removetheretainingcapfromtheowmeterbody
(Figure76).
Figure76
1.Retainingcap3.Flowmeterbody
2.Paddlewheelassembly
3.Carefullypullthepaddlewheelassemblyfromthe
body.
4.Usewarmwater,asoft-bristledbrush,andamild
detergentasnecessarytocleantheowmeterbody
andpaddlewheel.Removeanysmallmetallicdebris.
Important:Donotusesolventsorfueltoclean
theowmeter.
5.Installthepaddlewheelassemblyintotheowmeter
body.
Important:Thepaddlewheelassemblywill
onlytintothebodyoneway,inadetentsloton
thesideofthebody.Donotforcethepaddle
wheelassemblyintothebodyinanyother
orientation.
6.Installtheretainingcap.
7.Connectthewiretotheowmeter.
CleaningtheSuctionStrainer
ServiceInterval:Beforeeachuseordaily(moreoften
whenusingwetablepowders)
1.Removetheretainerfromtheredttingattachedto
thelargehoseonthetopofthetank.
Figure77
1.Suctionstrainer
2.Disconnectthehosefromthetank.
3.Pullthestraineroutofthehole.
4.Cleanthestrainerwithcleanrunningwater.
5.Replacethestrainer,seatingitfullyintothehole.
6.Connectthehosetothetopofthetankandsecure
itwiththeretainer.
59