Greensmaster 1000/1600
Page 5 – 3
Electrical System
ABCDEF
GREEN
RED
BROWN
BROWN
CLUTCH
PRESENCE SWITCH
ENGINE
MAGNETO
CONNECTOR/
INTERLOCK MODULE
BLACK\WHITE
BLACK\WHITE
ON/OFF
IGNITION COIL/
IGNITOR
BLACK
BLACK
BLACK
Late Model Kawasaki FE120 Engines
ON\OFF switch is open in the ON position
CLUTCH SWITCH is closed when the clutch is DISENGAGED
HIGH TENSION LEAD
FLYWHEEL
with Operator Presence Control
BROWN
BLACK\WHITE
BLACK\WHITE
BROWN
SWITCH
OPERATOR
OPERATOR PRESENCE SWITCH is closed when the bail is held
RED
Note: There are two types of ignition coils used
on the Kawasaki FE120 engine. On older models,
a coil is used in conjunction with an igniter. On
newer models, a combination igniter/ignition coil is
used which has the igniter built into the ignition
coil.