EasyManua.ls Logo

Toro Greensmaster TriFlex 3300 - Fault 33: 48 Volt Keyswitch Undervolt - Reel Motor 1

Toro Greensmaster TriFlex 3300
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault33:48VoltKeyswitchUndervolt
ReelMotor1
InfoCenterDisplay:
____FAULT#33____
148V
KEYSWITCHUNDER
V
Important:Forthisfault,theterm“keyswitch”referstothe48Vlogicpowercircuit,nottothe
ignitionswitch.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
FaultDescription
Akeyswitchundervoltagefaultisreportedwhenthecuttingreelmotormeasuresthe48Vlogicvoltageatless
than32V.
CircuitDescription
Eachcuttingunithasanelectricreelmotorthatcontainsaninternalcontroller.Theinternalcontrollermeasures
asteady48Vsignal,calledlogicpower.
Ifonly1cuttingreelmotorisreportingakeyswitchundervoltfault,theproblemismorelikelytobewiththe48V
logicpowerconnectiontothatcuttingreelmotor.
Ifmorethan1cuttingreelmotorisreportingakeyswitchundervoltfault,theproblemismorelikelytobe
withthe48Vbusvoltage.
Ifmorethanonedeviceisreportingthisfault,checkthebatteryvoltagewiththeengineOFF,andagainwith
theenginerunning.
IfthebatteryvoltageisgoodwithengineOFFbutnotON,checktheStarter/Generator.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:ChecktheInfoCenterfortheReelsEnableindication.
TheReelsEnableindicationontheInfoCenterDiagnosticsscreenidentieswhethertheTEC-5001outputexists
toenergizethe48VLogicrelay.Thisrelayprovides48Vlogicpowertothereelmotorsandstarter/generator.
106