Fault132:InternalTECControllerFault
InfoCenterDisplay:
_____FAULT#132____
INT.DEVEL.
FaultDescription
TheprimaryT oroelectroniccontroller(TEC-5001)reportsthisfaultwhenitdetectsasoftwarefaultexists
withintheprimaryTEC.
CircuitDescription
TheprimaryTECcontrollermonitorstheconditionofvariousmachineswitchesandsensors(inputs)anddirects
electricalpowertocontrolmachinefunctions(outputs)basedonthestateoftheinputs.TheT1isprimarily
responsibleformanagingtheenginestartsignalandinterlocks.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Shutofftheengine.
3.Starttheengine.
4.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.ContacttheToroTechnicalAssistanceCenterforassistance.
Note:Youmustxthissoftwarefault.AccomplishtheTECsoftwarerepairwithdirectassistance
fromToro.