EasyManua.ls Logo

Toro Greensmaster TriFlex 3300 - Fault 47: Overtemp Bulb - Current too High

Toro Greensmaster TriFlex 3300
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault47:OvertempBulbCurrentTooHigh
InfoCenterDisplay:
____FAULT#47____
WARN-OVER
FaultDescription
ThisfaultisreportedwhentheovertempbulbcircuitisdrawingtoomuchcurrentfromtheTEC-5001controller.
Note:Theovertempbulbmayalsobereferredtoasthehighwatertemperatureindicatorlight.
CircuitDescription
OneoutputfromtheprimaryTECcontrollerdrivestheovertempindicatorbulb.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Testtheoutputcircuitforashort.
1.Openuptheoperatorconsoleasneeded,andremovethewarninglampassembly(Figure84).
147

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3300

Related product manuals