Fault81:StartRelayOvercurrent
InfoCenterDisplay:
_____FAULT#81____
RELAYCOIL-
OVER
FaultDescription
Outputcurrentvoltagetothestarterrelaycoilistoohigh.
CircuitDescription
WhenthekeyswitchisturnedtotheRUNorSTARTposition,asignalissentfromthekeyswitchtotheprimary
TEC,andthestartrelayisactivated.Whenthishappens,thekeyswitchmaybeturnedtotheSTARTposition
andthestartersolenoidwillbeengaged,whichwillactivatetheengine’sstartermotor.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
200