Fault104:OvercurrentDisableReelMotor
1
InfoCenterDisplay:
_____FAULT#104____
1-OVER
FaultDescription
Thisfaultcanbetriggeredonahardwareovercurrentorahardwareovervoltage.Thisistoprotectthissystem
inthecasethatthesoftwaredoesnotlimitthecurrentandvoltagecorrectly.
CircuitDescription
Thethreecuttingreelmotorsinthemachineareidentical48V,1100watt,brushless,permanentmagnet
motors.Eachmotorhasitsownintegralinverterandon-boardcontroller.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Swapcuttingreelmotorsbetweencuttingunits.
Allofthecuttingreelmotorsareidentical.
1.RefertoFigure146tolocatecuttingunit1.