EasyManua.ls Logo

Toro Greensmaster TriFlex 3300 - Fault 131: Internal TEC Controller Fault

Toro Greensmaster TriFlex 3300
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault131:InternalTECControllerFault
InfoCenterDisplay:
_____FAULT#131____
INT.DEVEL.
FaultDescription
TheprimaryT oroelectroniccontroller(TEC-5001)reportsthisfaultwhenitdetectsasoftwarefaultexists
withintheprimaryTEC-5001.
CircuitDescription
TheprimaryTEC-5001controllermonitorstheconditionofvariousmachineswitchesandsensors(inputs)and
directselectricalpowertocontrolmachinefunctions(outputs)basedonthestateoftheinputs.Theprimary
TECisresponsibleformanagingtheenginestartsignalandinterlocks.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Shutofftheengine.
3.Starttheengine.
4.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.ContacttheToroTechnicalAssistanceCenterforassistance.
Note:Youmustxthissoftwarefault.AccomplishtheTECsoftwarerepairwithdirectassistance
fromToro.
306

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3300

Related product manuals