Fault24:CANBusFaultReelMotor2
InfoCenterDisplay:
____FAULT#24____
2FAULT
FaultDescription
ThisfaultisreportedwhentheTEC-5001losescommunicationwithcuttingunit2for1.5seconds.If
communicationisneverestablished,afaultisreported2.5secondsafterpowerisrstturnedon.
Note:Thisfaultisprobablyincludedamongallofthecuttingreelmotorssettingrelatedfaultsinrapid
succession.Beginthediagnosiswiththerstcuttingreelmotortoreportafault.
CircuitDescription
All3cuttingreelmotorsareconnectedtothe48VCANbus.All3cuttingreelmotorsfunctionsimultaneously.
When1cuttingreelmotorisaffectedbyaCANbusfault,allofthecuttingreelmotorsaredisabledandthe
machineisunabletomow.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Inspectthewiringforcuttingreelmotor2.
1.RefertoFigure44tolocatecuttingreelmotor2.